European Windows in Ottawa: Triple-Glazed Tilt and Turn for Cold Winters
InterHaus supplies and installs Austrian-made Internorm windows and doors in Ottawa, for renovations, custom homes and Passive House projects. This page covers the models we would look at first, how the Ontario code treats them, and how a job runs when the showroom is in Oakville and the house is not.
Last updated November 24, 2026 · Reviewed by InterHaus product specialists
The short answer
InterHaus supplies and installs European windows in Ottawa as the official Internorm dealer in Canada, working from its Oakville showroom and Ontario warehouse. Triple-glazed tilt and turn windows reach a Uw as low as 0.62 W/m²K on the KF 410. You can order supply only, supply and install, or supply with on-site supervision. A private residence renovation in Ottawa is among our projects.
What European windows in Ottawa need to do first
A long heating season tests three things in a window: how much heat passes through the frame and glass, how well the sash seals when the wind is on it, and how warm the inner pane stays when the furnace is working hard. By Natural Resources Canada’s estimate, up to 25% of a home’s energy loss can be through its windows, doors and skylights, so the choice shows up in comfort as well as on the gas or hydro bill.
European windows approach all three as one assembly. An Internorm uPVC or uPVC/aluminum frame has six internal chambers and three layers of perimeter gaskets as standard, around a triple-glazed unit. On a tilt and turn window, concealed hardware pulls the closed sash onto those gaskets along its edges, rather than at a single latch.
The result is measured by Uw, the U-value of the whole window in W/m²K, where lower is better. The best published figures in our Internorm range run from 0.62 to 0.79. Your own figure depends on the size, glass and opening type of each unit, which is why we quote from a window schedule and not from a brochure number.

Renovation Private Residence, Ottawa
Our projects page lists a renovation of a private residence in Ottawa. The photo is from that house: a pair of black-framed windows over the kitchen sink, looking out to the garden, taken before the interior trim went on.
The unfinished edge is the useful part. Flashing membrane is visible around the opening, where the new frame meets the old wall. In a renovation that joint matters as much as the window, because a well-insulated frame set in a leaky opening will still feel drafty.
It also shows a detail worth drawing early. Tilt and turn sashes open into the room, and a kitchen tap stands right in their path. Mark taps, deep counters and blinds on your window list, and we can suggest where a tilt-only or fixed unit makes more sense.
Which Ontario climate zone applies in Ottawa
Ontario’s energy rules for houses, SB-12, use two zones. Zone 1 is below 5,000 heating degree-days and Zone 2 is 5,000 or more. The zone follows the degree-day value that the province’s SB-1 climate table gives for the location of the building, so it depends on the site. Ask your designer or energy advisor to write the SB-1 value and the zone on the drawings before windows are specified.
The zone matters because it changes the target. The table below shows what the prescriptive packages ask for when the home has a furnace of 92% AFUE or better. The packages apply where glazing is no more than 17% of the wall area. Between 17% and 22% the window U-value has to improve by one step, and above 22% the design moves to the performance path.
A separate minimum sits in Part 9. Where the January design temperature falls between −15 °C and −30 °C, windows and doors need a U-value of 2.0 W/m²K or lower, or a Temperature Index of at least 68, and where SB-12 is stricter, SB-12 governs.
SB-12 window targets: Zone 1 and Zone 2
Maximum U-value in W/m²K, with the minimum Energy Rating (ER) that can be used instead, for windows and sliding glass doors.
| Zone 1 (under 5,000 HDD) | Zone 2 (5,000 HDD or more) | |
|---|---|---|
| New home, furnace AFUE 92% or better | 1.6 (ER 25) in five of six packages, 1.4 (ER 29) in one | 1.2 to 1.6 (ER 34 to 25), by package |
| New home, electric space heating | 1.2 to 1.6 (ER 34 to 25), by package | 1.2 or 1.6 (ER 34 or 25), by package |
| Addition, not electrically heated | 1.6 (ER 25) | 1.4 (ER 29) |
| Addition, electric heat | 1.4 (ER 29) | 1.4 (ER 29) |
Code values are determined under CSA A440.2 or NFRC 100/200. They are not the European Uw figures quoted elsewhere on this page.
European Uw and Canadian ratings are different tests
Internorm declares Uw by European methods, with 0 °C outside and 20 °C inside. The North American NFRC method uses −18 °C and 21 °C. RDH Building Science compared the two and found that values for the same frame and glass can differ by up to 25%, so a Uw of 0.62 cannot simply be dropped into a permit form.
ENERGY STAR Canada version 5 asks for a U-factor of 1.22 W/m²K or lower, or an ER of at least 34, and only a certified model counts. If your permit, energy model or rebate needs a Canadian rating, tell us at the quote stage so we can check what is available for the exact units. Our U-value and ratings guide explains each term.
On rebates, Ontario’s Home Renovation Savings Program offers $100 per rough opening when the new window or door is ENERGY STAR certified. It needs an energy assessment before work begins and at least two qualifying upgrades, and its terms require final assessments to be booked by November 30, 2026, so a project starting now should not budget on it unless the program site shows a new date.
Triple-glazed European windows we would price for an Ottawa house
Best published values for each model, from the InterHaus product pages and data sheets. Sound and Uw change with the glass you choose.
| Frame | Uw as low as (W/m²K) | Sound reduction | Depth | Security | |
|---|---|---|---|---|---|
| KF 410 | uPVC/aluminum | 0.62 | 34–47 dB | 93 mm | RC 2 |
| KF 520 | uPVC/aluminum, flush studio look | 0.63 | 33–46 dB | 93 mm | Up to RC 3 |
| HF 410 | Timber inside, aluminum outside | 0.64 | 33–46 dB | 85 mm | RC 2 |
| KV 440 | uPVC/aluminum, blind between panes | 0.64 | 39–45 dB | 93 mm | RC 2 |
| Schüco AWS 90.SI+ | All aluminum | 0.71 | up to 45 dB | 100 mm | Concealed locking |
| Reynaers MasterLine 10 | All aluminum | 0.8 | up to 44 dB | 97–107 mm | Concealed locking |
Uw is the European (EN ISO 10077) rating for each system’s best configuration.
Why tilt and turn windows suit Ottawa homes
One handle, two ways to open, and a sash that seals all round when shut.
Air without an open window
Tilted in at the top, the sash lets a bedroom breathe on a mild day while it stays held at the bottom.
Cleaned from indoors
Turned in like a door, the outer pane is within reach on an upper floor, with no ladder in a snowy flower bed.
A warmer inner pane
Triple glazing with a low-e coating keeps the room-side glass warmer, which cuts the chill beside it and the risk of condensation.
Quieter rooms
The KF 410 is published at 34–47 dB, with the glass build-up deciding where in that range you land.
Blinds the snow cannot reach
On the KV 440 the blind sits between the panes, out of the dust and weather.
A frame for the house
uPVC, uPVC/aluminum, timber/aluminum or all aluminum, in profiles from square-edged to soft.
European entrance and patio doors for Ottawa
The door is often the coldest thing on the ground floor, so treat it with the same care as the windows. Internorm aluminum entrance doors are thermally broken through frame, panel and threshold; the AT 530 reaches 0.75 W/m²K and the AT 540 0.78. The timber/aluminum HT 410 goes to 0.58, the best figure among our entrance doors.
For the garden side, the KS 430 lift and slide door in uPVC/aluminum reaches a Uw of 0.64 W/m²K with elements up to 6500 × 2800 mm, and the timber/aluminum HS 330 reaches 0.73. Our European doors guide compares the full range.
How a project runs from Oakville to an Ottawa site
Most early work can happen by email and phone, so the distance mostly affects delivery and site visits. We plan both at the start.
- 01
Send drawings or photos
A window schedule and elevations for a new build; photos, rough sizes and a list of rooms for a renovation.
- 02
Choose the system
Our product specialists, who have an architectural background, suggest frames and glazing room by room. Visit the Oakville showroom if you want to work the hardware first.
- 03
Agree the service
Supply only, supply and install, or supply and supervision. The choice shapes who measures, who fits and what your own contractor needs to prepare.
- 04
Quote and sign off
Each opening is listed with its series, size, glass and options. Passive House projects get a quote within 72 hours.
- 05
Made in Austria, held in Ontario
Internorm builds to measure at its Austrian plants. Orders come into our Ontario warehouse, and delivery to the site is coordinated with you or your builder.
- 06
Fit, check and look after
The installation is checked with you at handover. After-sale service covers adjustments and small repairs such as hinge greasing and hardware tuning.
Three ways to have the work done
These are the same three services described on our About page.
Supply only
For builders and contractors with their own installers. We handle logistics and bring the windows from our local warehouse to the site, with delivery coordinated with your schedule.
Supply and install
Our qualified fitters place every window and door, and we manage the job from delivery to handover. Ottawa is listed among our supply and install areas.
Supply and supervision
A third party installs and our team comes to site for a few days to guide handling, fitting and finishing. This suits a custom home with a trusted local crew.
Passive House windows for an Ottawa build
The Passive House Institute sets different limits by climate zone. The cool-temperate limit is a Uw of 0.80 W/m²K for the window itself and 0.85 installed; in the cold zone, the limits drop to 0.60 and 0.65. Both use a reference window of 1.23 × 1.48 m. Which zone your site falls in is a question for your Passive House consultant.
The Internorm KF 410 is certified by the Passive House Institute, in both its uPVC and uPVC/aluminum versions. Its 0.62 W/m²K is the best published figure and not a certificate value, so ask us for the certificate for the configuration you want, particularly if the model uses the cold-zone limits. Schüco AWS 90.SI+ and Reynaers MasterLine 10 are available in PHI certified configurations when an all-aluminum frame is wanted.
What to send for an Ottawa quote
The more of this you have, the fewer rounds of questions before a price.
| Drawings | Floor plans, elevations and wall sections, with the SB-1 value and zone if known |
|---|---|
| Window list | Width, height, opening type and room for each opening |
| Photos | Each side of the house and each opening from inside, for a renovation |
| Wall type | Brick, stone, siding or stucco, and where the insulation sits |
| Priorities | Cold rooms, street noise, a view, security, or a Passive House target |
| Permits | Permit or heritage status, confirmed with the City of Ottawa or your designer before ordering |
| Service | Supply only, supply and install, or supply and supervision |
Lead times depend on the order, so ask for the current one with your quote.
“My preferred window supplier for any of our projects with ambitious sustainability or indoor comfort goals. They have been easy to work with, and responsive when I need a problem solved. Internorm products have served me well, and these are the best, most reliable suppliers I have found in eastern Canada.”
Ottawa window questions
Yes. Ottawa is listed among InterHaus supply and install areas. You can also choose supply only, or supply with our team supervising your own installer on site for a few days.
Yes. The InterHaus projects page lists a renovation of a private residence in Ottawa, and a photo from it appears on this page.
It depends on the site. SB-12 Zone 1 is under 5,000 heating degree-days and Zone 2 is 5,000 or more, using the SB-1 value for the location. Your designer can confirm it on the drawings.
Look for a whole-window Uw well under 1.0 W/m²K and check it is for the size and glass you are buying. Internorm models run from 0.62 on the KF 410. For permits, ask for the CSA or NFRC rating, because the two scales are not interchangeable.
No. Drawings, photos and calls can cover most of the process. The Oakville showroom at 217 Speers Rd. is there if you want to open a tilt and turn sash or compare frame samples before you order.
Yes. Order supply only, or supply and supervision if you want our team on site for a few days while your crew learns the system. Agree who takes final measurements and prepares the openings before the order is placed.
InterHaus quotes each project opening by opening, so we do not publish a price per window. Size, frame material, glazing, opening type and the service you choose drive the total. Our European windows cost guide explains the factors and cites published ranges.
Planning windows for an Ottawa home?
Send your drawings, or photos and rough sizes, and tell us which service you need. We will recommend a system for each opening and prepare an itemized quote.
Sources
Code, rating and program details, checked November 10, 2026.
- SB-12 Energy Efficiency for Housing · Government of Ontario · Zones, packages and additions
- SB-1 Climatic and Seismic Data · Government of Ontario · Where to look up the value for your site
- Part 9 Housing and Small Buildings · Government of Ontario · Table 9.7.3.3
- Windows, doors and skylights · Natural Resources Canada · Share of home energy loss
- ENERGY STAR Canada technical specification · Natural Resources Canada
- Energy Performance of Windows: Navigating North American and European Window Standards · RDH Building Science · Test conditions and the 25% range
- Certification Criteria: Transparent Building Components · Passive House Institute
- HRSP Assessment Terms and Conditions · Enbridge Gas and IESO
Written and maintained by the InterHaus product team at our Oakville showroom. InterHaus is the official Internorm dealer in Canada, and our product specialists have an architectural background. Product figures come from Internorm’s 2026/27 catalogue and official data sheets; building code and incentive details come from public sources such as Natural Resources Canada and the Province of Ontario.
Last updated November 24, 2026 · How we write our pages · Visit the showroom · +1 (437) 826-2067