Official Internorm dealer in Canada · Showroom 217 Speers Rd. Unit 8, Oakville +1 (437) 826-2067Toll-free (888) 770-4917 info@interhaus.ca
Blog · Energy efficiency

Energy-Efficient Windows in Canada (2026): What Actually Cuts Heating Bills

Ratings, frames, glass and installation all decide how much heat a window saves. Here is which numbers matter for ENERGY STAR windows and energy efficient windows in Ontario, and where your money does the most work.

2026/27 catalogue

The short answer

Energy-efficient windows in Canada are rated by U-factor (heat loss, lower is better), Energy Rating (ER, higher is better) and air leakage. ENERGY STAR Canada certifies windows at U 1.22 W/m²K or less, or ER 34 or more. Real heating savings also depend on the frame, the spacer, glass chosen for each orientation and an airtight installation, which InterHaus in Oakville, Ontario supervises.

Start here

What makes a window energy efficient in a Canadian winter

Shopping for energy efficient windows in Canada usually starts with one number on a label, but a window handles heat in three ways. It conducts heat through the glass and frame, measured by the U-factor. It leaks air through the sash and around the frame: the product’s air leakage rating covers the first, and no rating covers the installation. And it admits sun, measured by the solar heat gain coefficient (SHGC), which in a Canadian January is free heat.

These pull in different directions, so the best window for a north bedroom is not always the best for a south living room. Natural Resources Canada (NRCan) says windows, doors and skylights can account for up to 25% of a home’s energy loss. Definitions and conversions are in our window U-value and ratings guide; this post is about using them when you buy.

Choosing a level

Energy efficient windows in Canada: four levels to know

From the floor up, the four benchmarks worth knowing.

Ontario Building Code

SB-12 sets the minimum for new houses. Most GTA packages for a high-efficiency furnace allow windows at U 1.6 W/m²K or ER 25: a floor, not a target.

ENERGY STAR

U 1.22 or less, or ER 34 or more. NRCan says certified windows are about 20% more efficient than the average window. Ontario’s rebate requires this level.

ENERGY STAR Most Efficient

U 1.05 or less, or ER 40 or more, under the 2025 criteria. NRCan says these are up to 55% more energy efficient than average models.

Passive House

The Passive House Institute’s own method: a component Uw of 0.80 W/m²K or less under its cool-temperate criteria, and 0.60 under its cold-zone criteria.

ENERGY STAR windows

What the ENERGY STAR label tells you, and what it does not

ENERGY STAR Canada’s version 5.0, in force since January 1, 2020, also caps air infiltration and exfiltration at 1.5 L/s/m². Ratings must come from CSA A440.2 or NFRC 100/200, and certification belongs to a model, not a brand. The Uw on an Internorm data sheet is calculated to EN ISO 10077 and is not an ENERGY STAR value, so each model has to be checked against NRCan’s list.

Two points matter when you buy. The ER path rewards solar gain, so a high-SHGC window can certify with a weaker U-factor; that suits a sunny south wall, but on a north wall the U-factor is what counts. And the bar is moving: a version 6.0 draft, out for comment since October 2026, proposes U 1.05 with no ER path from January 1, 2029. That equals today’s Most Efficient U-factor limit, so a window bought at that level now already meets the proposal. NRCan has published no 2026 Most Efficient criteria; the 2025 set is the latest.

The building code

Energy efficient windows in Ontario: what the code asks for

Ontario’s 2024 Building Code, in force since January 1, 2025, sets window performance for houses in SB-12, which splits the province by heating degree-days (HDD): Zone 1 is under 5,000 and Zone 2 is 5,000 or more. Every GTA location in the code’s climate table is in Zone 1, from Toronto City Hall at 3,520 HDD to Vaughan (Woodbridge) at 4,100.

In Zone 1, with a gas furnace of 92% AFUE or better, five of the six packages allow U 1.6 W/m²K or ER 25 and one asks for 1.4 or ER 29; Zone 2 packages go down to 1.2 (ER 34). Above 17% glazing-to-wall area the limit tightens a step, and above 22% the house needs the performance path and an energy model, which is common for glassy custom homes in Toronto. A window at U 1.6 meets most GTA packages; ENERGY STAR needs 1.22.

Frames and spacers

Frames and spacers: the parts most quotes skip

On a high-performance window the frame loses more heat per square metre than the glass. On the KF 410 data sheet, the frame’s Uf is 0.92 W/m²K against Ug 0.5 for the triple glass.

Frame material

NRCan notes that metal frames conduct heat readily, while vinyl and fibreglass frames use multiple chambers. Internorm’s uPVC profiles have six; the HF series is a timber, thermal-foam and aluminum composite.

Insulated frame cores

I-tec Insulation fills the hollow frame chambers of the KF 410, KF 510 and KV 440 with insulating granulate, which Internorm says considerably improves thermal insulation.

Warm-edge spacers

The glass edge is a window’s coldest line. On the HF 410 sheet, edge loss (Psi) is 0.036 W/mK with Internorm’s Iso spacer and 0.075 with aluminum: Uw 0.71 against 0.81 with the same glass.

Gaskets and opening type

Internorm windows have three circumferential gaskets. NRCan notes that hinged windows, tilt and turn included, are more airtight than sliders, and fixed windows more airtight still.

Internorm windows compared: Uw, depth and sound

Best-case Uw with triple glazing, from each model’s data sheet. Use it to compare Internorm models with one another.

FrameUw as low as (W/m²K)Depth (mm)Sound reduction (dB)
KF 310uPVC0.697133–45
KF 410uPVC0.629034–47
KF 410uPVC/aluminum0.629334–47
KF 510uPVC0.639034–46
KF 520uPVC0.639033–46
HF 410Wood/aluminum0.648533–46
HF 510Wood/aluminum0.658535–47
HF 520Wood/aluminum0.719035–47
HV 450 (integrated blinds)Wood/aluminum0.628539–46
HX 300 (fixed glazing)Wood/aluminum0.7410034–47
HS 330 (lift and slide door)Wood/aluminum0.7320932–40

Uw is calculated to EN ISO 10077, not CSA A440.2 or NFRC, so it cannot be set against ENERGY STAR or SB-12 limits. The Uw in your quote depends on the glass, spacer and frame options chosen.

Reading the table

Why the best window on paper is not always the best buy

The spread is narrow, from 0.62 on the KF 410 and HV 450 to 0.74 on the HX 300, so the choice turns on frame material, sightlines, security and sound. The 71 mm KF 310 suits renovations where a deeper frame would crowd the opening; the KF 410 is the Passive House Institute certified choice for new builds; and the HF 410 puts wood on the inside at 0.64.

Airtightness and installation

Installation: the biggest real-world factor

Every rating above describes a window on its own. None covers the joint between window and wall, and that joint decides whether the window performs as rated. A well-rated frame set in a rough opening with open gaps still lets cold air in, usually behind trim where nobody sees it until the drafts start.

The Government of Canada’s Keeping the Heat In guide says window and door frames are incorporated into the air barrier by sealing them to the adjoining materials, and recommends only low-expansion foam around frames to avoid bowing them. The Passive House Institute puts it in numbers: its cool-temperate criteria allow a component Uw of 0.80 W/m²K but an installed Uw of 0.85, because even a correct installation adds heat loss at the joint. Internorm’s installation sequence says the same: the correct building connection and joint ensure airtightness between window and masonry. That is why InterHaus offers installation guidance and supervision, not only supply.

What InterHaus checks on a site measure and installation

Whether our fitters install or we supervise your own installer:

  1. 01

    Measure and survey

    Internorm windows are made to measure in Austria, so each opening is measured and its structural conditions checked before ordering.

  2. 02

    Place the window in the wall

    We agree with the builder or architect where the frame sits, in line with the insulation, so the air barrier can connect to it.

  3. 03

    Seal the joint

    An air seal on the room side, low-expansion insulation in the gap, and a weather seal outside against wind-driven rain.

  4. 04

    Adjust and test

    Sashes are adjusted so the gaskets close evenly, and every window is checked with you before handover, with care advice for gaskets and hardware.

South glass vs north glass: choosing glazing by orientation
Glazing for Canadian climates

South glass vs north glass: choosing glazing by orientation

In winter the sun sits low in the southern sky, so south-facing glass collects useful heat on clear days. North windows get no direct winter sun and only lose heat, so the lowest U-value is the whole story there. West glass takes low evening sun and is the usual source of summer overheating.

So SHGC is a choice per elevation. NRCan advises caution with SHGC above 0.45 on south- or west-facing windows, especially where glass outweighs wall, because rooms can overheat and cooling costs rise. Internorm’s standard triple glazing has a centre-of-glass g-value of 53% at Ug 0.5, and its laminated security build-ups 47%; whole-window SHGC is lower than centre-of-glass g. For large south or west glass, movable shading such as integrated blinds beats permanently darker glass.

Cold-climate checklist

Best windows for a cold climate: what to prioritise

If the budget forces choices, this is the order we suggest:

  • An airtight, insulated installation. Without it, no rating reaches your heating bill.
  • Triple glazing with low-E coatings and gas fill. NRCan says triple-glazed products can be up to 50% more efficient than double-glazed, and that low-E coatings cut heat loss and heat gain by up to 30%.
  • An insulated frame and warm-edge spacer. They keep the frame and glass edge warmer, which is where condensation starts.
  • Hinged or fixed rather than sliding. A closed tilt and turn sash presses its gaskets against the frame.
  • Glass matched to orientation. Solar gain where winter sun reaches, the lowest U-value on the north.
Passive House-level windows: when they make sense
Passive House windows

Passive House-level windows: when they make sense

Passive House Institute certification is the strictest window standard most Canadians will meet. Its cool-temperate criteria ask for a component Uw of 0.80 W/m²K or lower and a hygiene factor (fRsi) of at least 0.70, which keeps inside surfaces warm enough to resist condensation and mould; the cold-zone criteria go to 0.60. Your Passive House designer confirms which set applies.

These windows pay off most when the walls, roof and airtightness reach the same standard: a new build, an addition or a deep retrofit. In an otherwise drafty house they still give warmer glass and quieter rooms, but the weakest part of the envelope sets the bill. InterHaus projects include the Etobicoke Passive House Residence in Toronto and a Passive House residence in Niagara-on-the-Lake, and Passive House projects get a quote within 72 hours.

Payback

Payback: how to judge it without made-up numbers

Window ads often promise a fixed cut in your heating bill. We do not, because the answer depends on things a brochure cannot know: your current windows, your heating fuel and its price, your climate (Toronto City Hall has 3,520 heating degree-days; Ontario’s Zone 2 starts at 5,000) and how airtight the rest of the house is.

NRCan’s 20% for ENERGY STAR and up to 55% for Most Efficient compare products, not bills. For a figure that fits your house, use the energy advisor’s before-and-after assessment a rebate requires anyway. Then add what never shows on a bill: glass you can sit beside in January, panes free of condensation, sound reduction of up to 47 dB on the KF 410, and Internorm’s 30-year repair assurance. Budget ranges are in our European windows cost guide.

“Excellent windows and doors for noise and heating and cooling. We had to install new windows in some rooms in our old house and the difference between these ones and our old ones was obvious right away, no condensation in the winter, much quieter in summer (we had very noisy neighbours), very little heat loss so the rooms were warmer in winter and cooler in summer. We were so impressed that we installed them throughout our new house. Viktoryiya was so easy to work with, and the installation was excellent and problem free!”
Bruno Rachiele · Google review
Incentives, November 2026

Rebates for energy-efficient windows in Ontario

As of November 13, 2026, we found no federal program open in Ontario that funds window replacement. The main option is the provincial utility rebate; confirm the details before you sign:

  • Home Renovation Savings Program: Enbridge Gas and the IESO pay $100 per rough opening for ENERGY STAR certified windows and doors, from a minimum of three window openings or one door, in detached, semi-detached, row and townhomes (not new builds). It needs a registered energy advisor’s assessment before work starts and at least one other qualifying upgrade, such as insulation or air sealing.
  • Caps and deadlines: up to $5,000 for homes heated with Enbridge natural gas and $10,000 for electric, oil, propane or wood heat. The program’s November 2025 terms require post-renovation audits to be scheduled by November 30, 2026 and completed by December 31, 2026.
  • European windows: eligibility follows ENERGY STAR certification of the exact model, not a European Uw, so ask us to confirm each model in your quote. Toronto owners can also look at the City’s financing program, covered on our Toronto page.
How we work

How InterHaus specifies energy-efficient windows

InterHaus is the official Internorm dealer in Canada, with a showroom at 217 Speers Rd. Unit 8 in Oakville and local warehousing in Ontario. Our product specialists have an architectural background and support architects, builders and energy modellers with data sheets for each glass build-up, Passive House Institute certified window systems and PHI accredited Lunch & Learn sessions.

Before proposing a window we ask which way each elevation faces, what the wall build-up is, and what the target is: code, ENERGY STAR and rebates, or Passive House. The answers set the frame, the glass for each orientation and the installation detail, and show where a simpler window will do.

Energy-efficient windows: common questions

NRCan ranks fixed windows as the most airtight, then hinged types such as casement and tilt and turn, then sliders. Look for triple glazing with low-E coatings and gas fill, an insulated frame, a warm-edge spacer and, for the top tier, ENERGY STAR Most Efficient ratings of U 1.05 or ER 40.

For most replacements, yes. NRCan says certified windows are about 20% more efficient than the average window, and certification is required for the Home Renovation Savings rebate. The ENERGY STAR limit of U 1.22 W/m²K is also well beyond the 1.6 that most GTA code packages allow.

They cut heat loss through the windows, which NRCan says can be up to 25% of a home’s energy loss. Your saving depends on the windows replaced, your fuel, your climate and the airtightness of the rest of the house; an energy advisor’s assessment estimates it for your home.

Often, yes. South glass gains useful heat from the low winter sun, so higher solar gain helps there, while north glass only loses heat and needs the lowest U-value. NRCan advises caution with SHGC above 0.45 on south or west windows in very glassy rooms.

A great deal, though no window rating measures it. The frame must be sealed to the wall’s air barrier and the gap insulated, or air leaks around even a well-rated window. Passive House criteria allow Uw 0.85 installed against 0.80 for the window alone, so even good installation adds some loss.

In Ontario, the Home Renovation Savings Program pays $100 per rough opening for ENERGY STAR certified windows combined with another upgrade and an energy assessment. Its published terms end in December 2026, so check the current deadline. We found no federal window program open in Ontario in 2026.

Plan windows that cut your heating bill

Send drawings or a list of openings with the direction each wall faces, and tell us your target: code, ENERGY STAR or Passive House. A product specialist will propose Internorm models, the glass for each elevation and the installation detail.

+1 (437) 826-2067

Sources

Internorm figures come from the model data sheets. Pages checked November 10–13, 2026.

  1. Windows, doors and skylights ENERGY STAR Canada technical specification · Natural Resources Canada
  2. Windows, doors and skylights: ENERGY STAR certified products · Natural Resources Canada
  3. ENERGY STAR Most Efficient criteria: windows and sliding glass doors · Natural Resources Canada
  4. ENERGY STAR Canada fenestration specification, version 6.0 draft · Environment and Climate Change Canada · draft, not in force
  5. Technology primer: windows, doors and skylights · Natural Resources Canada
  6. Keeping the Heat In · Government of Canada
  7. SB-12 Energy Efficiency for Housing · Government of Ontario
  8. SB-1 Climatic and Seismic Data · Government of Ontario
  9. Criteria for certified Passive House components: transparent building components, v5.2 · Passive House Institute
  10. Home Renovation Savings Program: additional program eligibility requirements (November 2025) · Enbridge Gas and IESO
About this page

Written and maintained by the InterHaus product team at our Oakville showroom. InterHaus is the official Internorm dealer in Canada, and our product specialists have an architectural background. Product figures come from Internorm’s 2026/27 catalogue and official data sheets; building code and incentive details come from public sources such as Natural Resources Canada and the Province of Ontario.

Last updated November 13, 2026 · How we write our pages · Visit the showroom · +1 (437) 826-2067

Call us